Monday, May 4, 2015

Loctite 545 Equivalent Hydraulic/pneumatic Thread Sealant 


        Loctite 545  Equivalent Hydraulic/pneumatic Thread Sealant 

                                                                             from Tina(hengying@cnhybond.com  0086-18927302778  Skype:hengying11)



1:Product Description
CNHYBOND 545 provides the following product characteristics:
Technology: Acrylic
Chemical Type: Methacrylate Ester
Appearance (uncured): Purple liquidS
MSComponents: One component - requires no mixing
Viscosity: Medium
Cure : Anaerobic
Secondary Cure: Activator
Application :Thread sealing
Strength: High

CNHBOND 545 is designed for the locking and sealing of metal pipes and fittings ,the product cures when confined in the absence of air between close fitting metal surfaces and prevents loosening and leakage from shock and vibration,This product is specially formulated to offer lubricity for easy assembly

2:Typical properties of uncured material
Specific Gravity@25℃                              1.02
Viscostiy,Brookfield-RVT,25℃,mpa.s(cp):         8000-22000

3:Typical Performance of Cured Material
Adhesive Properties
After 24 hours @ 22 °C
Breakaway torue,iso 10964
M10 steel nuts and boltsS:     N.m                        2
Compressive Shear strength ,iso 10123:
Steel pins and colars                                              N/mm2         >1.50

4:For Assembly
(1). For best results, clean all surfaces (external and internal) with a HYBOND  cleaning solvent and allow to dry.
(2). If the material is an inactive metal or the cure speed is too slow, spray with Activator  7649™ and allow to dry.
(3)Apply a 360° bead of product to the leading threads of the male fitting, leaving the first thread free ,force the material into the threads to  thouroughly  fill the voids ,For bigger threads and voids, adjust product amount accordingly and apply a 360° bead of product on the female threads also
(4)Using accepted trade practices ,assemble and wrench tighten fitting until proper alignment is obtained
(5). Properly tightened fittings will seal instantly to moderate pressures, For maximum pressure resistance and solvent resistance allow the product to cure a minimum of 24 hours

5:For Disassembly
(1). Remove with standard hand tools
(2). Where hand tools do not work because of excessive engagement length or large diameters(over 1),apply localized heat to approximately 250℃,Disassemble while hot product.


6:For Clean up
Cured product can be removed with a combination of soaking in a HENG YING solvent and mechanical abrasion such as a wire brush.

7:Storage
Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties. Material removed from containers may be contaminated during use. Do not return product to the original container.HYBOND Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than those previously indicated. If additional information is required, please contact us.

8:Note
The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons
against any hazards that may be involved in the handling and use thereof. In light of the foregoing, HENYING Corporation specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of HENG YING Corporation’s products. HENG YING Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits. 